Power quality & electrical protection
From incoming supply monitoring to harmonic filtering, reactive power compensation and circuit protection. Find equipment by system voltage, load conditions and installation point.
Find a product by model
Search by model, product name or abbreviation such as AHF, SVG or SPD.
Xi’an, China
About Sucobell
Power quality and electrical protection products designed, manufactured and tested in China, with engineering support for site applications.
Our engineering team works with your equipment list, site measurements and installation conditions to review product selection.
Explore our company
- Years of power electronics experience
- 20+
- Units delivered
- 45,000+
- kvar of aggregate reactive power compensation
- 10,000,000+
Product Categories
Compare equipment for measurement, compensation and protection, or go directly to representative products in each category.
Browse by application
See where to measure or install equipment, which products to consider and what site information to bring.

Power Quality for Data Centers
Monitor the main incomer and UPS inputs, then assess filtering for cooling drives and reactive compensation on the main bus.

Industrial Motor Drives & Protection
Measure harmonics on the supply side of variable-frequency drives. Review motor protection separately for direct-on-line and drive-fed circuits.

Solar PV DC Surge Protection
Select a photovoltaic surge protective device (SPD) using the maximum string open-circuit voltage, DC cable route and inverter requirements.

Low-Voltage Capacitor Bank Retrofit
Size low-voltage capacitor bank stages from measured reactive demand and check the harmonic spectrum before choosing capacitors, reactors and switches.

AC and DC Power Supply Surge Protection
Select separate surge protective devices (SPDs) for an industrial cabinet’s AC supply and non-PV DC feeders based on circuit voltage, earthing and existing protection.
Sucyc-AHF Active Harmonic Filter (IGBT)
The IGBT-based Sucyc-AHF compensates 2nd–50th order harmonics and supports reactive power compensation and three-phase load balancing. Module options range from 30–200 A, depending on system voltage.
- Rated voltage
- 200 / 400 / 480 / 690 / 800 V
- Rated frequency
- 50 / 60 Hz (−10% to +10%)
- Capacity options
- 30 / 50 / 75 / 100 / 150 / 200 A per module

Find equipment for your project
Choose the problem you are working on to see the information to collect and the products or solutions to review.
Explore applicationsStart at the measurement point
Describe where the problem shows up and what the system was doing at the time.
- Location
- Identify the main incomer, distribution board or load feeder. Include a single-line diagram if available.
- Measurements
- Share the system voltage and the quantities you need to record, such as voltage, current or power factor.
- Event history
- Note when the disturbance occurs, which loads were running and any existing readings or event logs.
Match the equipment to the measured load
Use readings from a representative operating period to assess filtering and compensation needs.
- Load profile
- List major loads such as motor drives, rectifiers and UPS units. Note when each load runs.
- Measured demand
- Include available harmonic current spectra, power factor and reactive power readings.
- Existing equipment
- List installed filters or capacitor banks and the cabinet space available for additional equipment.
Identify the circuit you need to protect
The circuit type and installation point help narrow the range of suitable protection devices.
- Circuit type
- Identify the AC, DC, photovoltaic or motor circuit and provide the operating voltage from the drawing or nameplate.
- Equipment and protection
- Provide the equipment model or nameplate and list the protection devices already installed on the circuit.
- Installation point
- Indicate whether protection is needed at the incoming panel, in a downstream enclosure or near the load.
Engineering resources
Use the selection guides to review your measurements, then find technical documents by product model.
How to Choose an Active Harmonic Filter
Start with measurements at the point you want to protect, then define the compensation target and installation conditions.
Read the guideAPF and SVG: Choosing the Right Approach
Use harmonic measurements and reactive load data to decide where active filtering or reactive power compensation fits.
Read the guideProduct Document Library
Search by model for published datasheets, installation guides and drawings. Use the product model when requesting a document.
Find documents
Share your project requirements
Request a quote for multiple products in one inquiry. Enter the quantity and key specifications for each item.
Request a Quote- Equipment listProduct models and quantities for each item
- Key specificationsSystem voltage, rated capacity and mounting or wiring requirements
- Site informationLoad conditions and any available measurements or drawings