SCD20E P312PV PV DC Surge Protective Device

The SCD20E P312PV protects the DC side of photovoltaic installations against transient surges. It has a three-module Y configuration and is available in 1000, 1200 and 1500 V DC versions, each with a nominal discharge current of 20 kA (8/20 μs).

PV surge protection and DC isolation enclosure

Key specifications

Maximum continuous PV operating voltage (Ucpv)1000 / 1200 / 1500 V DC
Nominal discharge current (In, 8/20 μs)20 kA
Maximum discharge current (Imax, 8/20 μs)40 kA
Voltage protection level (Up)≤4.0 / ≤4.5 / ≤5.0 kV by model

Product highlights

  • MOV-based surge limiting for the DC side of photovoltaic systems.
  • Visual status indication and remote signaling for maintenance monitoring.
  • Replaceable plug-in protection modules.
  • Built-in thermal disconnection mechanism for overheated modules.

Technical specifications

Maximum continuous PV operating voltage (Ucpv)
1000 / 1200 / 1500 V DC
Nominal discharge current (In, 8/20 μs)
20 kA
Maximum discharge current (Imax, 8/20 μs)
40 kA
Voltage protection level (Up)
≤4.0 / ≤4.5 / ≤5.0 kV by model

Ratings by model

Scroll across to see all columns

SCD20E P312PV series ratings
ParameterSCD20E1000P312PVSCD20E1200P312PVSCD20E1500P312PV
Maximum continuous PV operating voltage (Ucpv)1000 V DC1200 V DC1500 V DC
Nominal discharge current (In, 8/20 μs)20 kA20 kA20 kA
Maximum discharge current (Imax, 8/20 μs)40 kA40 kA40 kA
Voltage protection level (Up)≤4.0 kV≤4.5 kV≤5.0 kV
Recommended backup fuse80 A gPV80 A gPV80 A gPV
PV short-circuit current rating (Iscpv)1000 A1000 A1000 A
Ingress protectionIP20IP20IP20
Operating temperature−40 to +85 °C−40 to +85 °C−40 to +85 °C

Model designation

The series uses the format SCD20E[Ucpv]P312PV.

SCD20E
Product series designation.
1000 / 1200 / 1500
Maximum continuous PV operating voltage in V DC.
P312
Three-module Y configuration.
PV
Variant intended for photovoltaic DC circuits.

Photovoltaic applications

Designed with reference to IEC/EN 61643-31 for surge protection on the DC side of photovoltaic installations.

Inverter DC inputs
Surge protection for the DC input circuits of photovoltaic inverters.
PV arrays and combiner boxes
Surge protection at DC distribution or collection points in photovoltaic installations, including distributed PV systems.
DC surge protection enclosures
A plug-in SPD option for PV array surge protection enclosures. Match the voltage rating and protection level to the DC circuit.

Suitability for other DC circuits, including energy storage systems, requires separate confirmation.

Surge protection modes

The three-module Y design covers common-mode surges from the positive or negative conductor to protective earth (PE) and differential-mode surges between the two DC conductors.

Selection questions

How do I choose between the three Ucpv ratings?

Check the maximum PV string open-circuit voltage at the site’s minimum design temperature. The selected Ucpv must account for that voltage and applicable project requirements. Also verify Up and the prospective short-circuit current at the intended location.

Which backup fuse is specified for this series?

The product data lists an 80 A gPV fuse. Confirm coordination with the selected model and the project’s DC protection design.

Can this PV SPD be used on a battery DC bus?

This series is intended for photovoltaic DC circuits. Confirm the product’s suitability for the specific battery or other non-PV DC circuit before selection.

How do I check the PV voltage rating?

For the SCD20E P312PV, compare Ucpv with the maximum PV string open-circuit voltage under site conditions and verify the DC earthing arrangement.

Request a project quote

  • Maximum string voltage under site conditions
  • System earthing and intended mounting point
  • Existing protection on the PV DC side
Share your requirements