The SCD20E P312PV protects the DC side of photovoltaic installations against transient surges. It has a three-module Y configuration and is available in 1000, 1200 and 1500 V DC versions, each with a nominal discharge current of 20 kA (8/20 μs).

Key specifications
| Maximum continuous PV operating voltage (Ucpv) | 1000 / 1200 / 1500 V DC |
|---|---|
| Nominal discharge current (In, 8/20 μs) | 20 kA |
| Maximum discharge current (Imax, 8/20 μs) | 40 kA |
| Voltage protection level (Up) | ≤4.0 / ≤4.5 / ≤5.0 kV by model |
Product highlights
- MOV-based surge limiting for the DC side of photovoltaic systems.
- Visual status indication and remote signaling for maintenance monitoring.
- Replaceable plug-in protection modules.
- Built-in thermal disconnection mechanism for overheated modules.
Technical specifications
- Maximum continuous PV operating voltage (Ucpv)
- 1000 / 1200 / 1500 V DC
- Nominal discharge current (In, 8/20 μs)
- 20 kA
- Maximum discharge current (Imax, 8/20 μs)
- 40 kA
- Voltage protection level (Up)
- ≤4.0 / ≤4.5 / ≤5.0 kV by model
Ratings by model
Scroll across to see all columns
| Parameter | SCD20E1000P312PV | SCD20E1200P312PV | SCD20E1500P312PV |
|---|---|---|---|
| Maximum continuous PV operating voltage (Ucpv) | 1000 V DC | 1200 V DC | 1500 V DC |
| Nominal discharge current (In, 8/20 μs) | 20 kA | 20 kA | 20 kA |
| Maximum discharge current (Imax, 8/20 μs) | 40 kA | 40 kA | 40 kA |
| Voltage protection level (Up) | ≤4.0 kV | ≤4.5 kV | ≤5.0 kV |
| Recommended backup fuse | 80 A gPV | 80 A gPV | 80 A gPV |
| PV short-circuit current rating (Iscpv) | 1000 A | 1000 A | 1000 A |
| Ingress protection | IP20 | IP20 | IP20 |
| Operating temperature | −40 to +85 °C | −40 to +85 °C | −40 to +85 °C |
Model designation
The series uses the format SCD20E[Ucpv]P312PV.
- SCD20E
- Product series designation.
- 1000 / 1200 / 1500
- Maximum continuous PV operating voltage in V DC.
- P312
- Three-module Y configuration.
- PV
- Variant intended for photovoltaic DC circuits.
Photovoltaic applications
Designed with reference to IEC/EN 61643-31 for surge protection on the DC side of photovoltaic installations.
- Inverter DC inputs
- Surge protection for the DC input circuits of photovoltaic inverters.
- PV arrays and combiner boxes
- Surge protection at DC distribution or collection points in photovoltaic installations, including distributed PV systems.
- DC surge protection enclosures
- A plug-in SPD option for PV array surge protection enclosures. Match the voltage rating and protection level to the DC circuit.
Suitability for other DC circuits, including energy storage systems, requires separate confirmation.
Surge protection modes
The three-module Y design covers common-mode surges from the positive or negative conductor to protective earth (PE) and differential-mode surges between the two DC conductors.
Selection questions
How do I choose between the three Ucpv ratings?
Check the maximum PV string open-circuit voltage at the site’s minimum design temperature. The selected Ucpv must account for that voltage and applicable project requirements. Also verify Up and the prospective short-circuit current at the intended location.
Which backup fuse is specified for this series?
The product data lists an 80 A gPV fuse. Confirm coordination with the selected model and the project’s DC protection design.
Can this PV SPD be used on a battery DC bus?
This series is intended for photovoltaic DC circuits. Confirm the product’s suitability for the specific battery or other non-PV DC circuit before selection.
How do I check the PV voltage rating?
For the SCD20E P312PV, compare Ucpv with the maximum PV string open-circuit voltage under site conditions and verify the DC earthing arrangement.
Request a project quote
- Maximum string voltage under site conditions
- System earthing and intended mounting point