Sucyc-AHF Active Harmonic Filter (IGBT)

The IGBT-based Sucyc-AHF compensates 2nd–50th order harmonics and supports reactive power compensation and three-phase load balancing. Module options range from 30–200 A, depending on system voltage.

Industrial electrical distribution room

Key specifications

Rated voltage200 / 400 / 480 / 690 / 800 V
Rated frequency50 / 60 Hz (−10% to +10%)
Capacity options30 / 50 / 75 / 100 / 150 / 200 A per module200/400 V: 30–200 A. 480 V: 50–200 A. 690/800 V: 100 A.
Wiring typeThree-phase, three- or four-wire
Mounting optionsWall-mounted / rack-mounted / floor-standing

Product highlights

  • Rated voltage options from 200 to 800 V
  • 2nd–50th order harmonic compensation, including the 2nd, 5th, 7th, 11th and 13th orders
  • Total response time below 10 ms
  • Parallel modules with optional N+1 redundancy

Technical specifications

Rated voltage
200 / 400 / 480 / 690 / 800 V
Rated frequency
50 / 60 Hz (±10%)
Compensation current per module
200/400 V: 30–200 A. 480 V: 50–200 A. 690/800 V: 100 A.
Harmonic compensation range
2nd–50th orders
Current THD (THDi) after filtering
<5% under typical conditions
Total response time
<10 ms
Additional specifications
Unit efficiency
≥97.5%
Wiring configurations
Three-phase three-wire or four-wire
Mounting options
Rack, wall or floor mounting
Enclosure protection
IP20

Topology, controls and communications

A three-level IGBT topology uses DSP and FPGA digital control with FFT harmonic analysis. The filter also supports reactive power compensation and three-phase load balancing.

Switching frequency
20 kHz typical
Power factor control
−1 to +1 (inductive and capacitive)
Overload capacity
110% continuous, 120% for 1 minute
Operator display
Optional 1.8-, 4.3- or 7-inch HMI
Communications
RS485 and CAN, plus RJ45 for inter-module connections
Current transformer sensing
Open- or closed-loop sensing, according to the project and its parallel control design.
Equipment protection
Overvoltage, undervoltage, overcurrent, overcompensation and inverter bridge faults

Installation conditions and parallel capacity

Use the system voltage, required compensation current and cabinet conditions to confirm the module combination.

Per-module compensation current
200/400 V: 30–200 A. 480 V: 50–200 A. 690/800 V: 100 A.
Cabinet capacity
Up to 5 modules and 1,000 A per cabinet, subject to configuration
Operating temperature
−25 to 55 °C, with derating above 45 °C
Relative humidity
5–95% RH, non-condensing
Installation altitude
Derating required above 1,500 m

Model codes and rack dimensions

For Sucyc-AHF-4L-400-100/R, 4L identifies three-phase four-wire, 100 is the rated compensation current in amperes, and R identifies rack mounting. The selection data groups the 200, 400 and 480 V options under the 400 code. Confirm the actual voltage and model when ordering.

Scroll across to see all columns

Selected rack-mounted modules
ModelVoltageCurrentW × D × H (mm)Weight
Sucyc-AHF-4L-400-100/R400 V100 A440 × 570 × 23035 kg
Sucyc-AHF-4L-400-150/R400 V150 A510 × 580 × 25043.5 kg
Sucyc-AHF-4L-400-200/R400 V200 A630 × 640 × 25065 kg
Sucyc-AHF-4L-690-100/R690 V100 A525 × 620 × 25055 kg

3L identifies three-phase three-wire. The 690 and 800 V options use their corresponding voltage codes. The standard IGBT designation has no S marker. The SiC designation includes S. W identifies wall mounting, and C identifies floor mounting.

Application conditions to review

690/800 V industrial distribution
Check the supply voltage and measured harmonic current for nonlinear loads such as rolling mills or crushers.
Production equipment and variable-speed drives
Measure the spectrum of drives, welders or rectifiers across representative production loads before choosing compensation current.
Rectifiers and single-phase loads
Include the 2nd order in the measurement and selection when it is present at the feeder.
UPS and power conversion equipment
Review the AC-side measurement points and operating modes for UPS systems, photovoltaic installations or charging equipment.
HVAC, lighting and lifts
Review the harmonic spectrum of HVAC drives, LED drivers and lifts at the intended compensation point in a commercial building.

Typical configurations

These examples illustrate how module combinations are selected. Size the actual installation from measured harmonic current, load profile and cabinet conditions.

690 V steel or mining distribution
Four 100 A rack-mounted Sucyc-AHF-4L-690-100/R modules provide a combined nominal compensation current of 400 A.
400 V production loads with 2nd-order harmonics
A three-module configuration with 100 A per module can be evaluated for rectifier and single-phase loads. Check the measured 2nd-order current and the other orders that need compensation.
400 V production lines with redundancy
Evaluate 150 A rack-mounted modules for groups of drives and welders. For N+1, check that the remaining modules can meet the required compensation current with one module unavailable.

Selection questions

How do I choose between the IGBT and SiC variants?

Start with system voltage, available space and the project’s response and efficiency requirements. The IGBT series includes 690 V and 800 V options. Compare the specifications for the exact SiC model for applications with tight space or demanding load changes.

What module current ratings are available at 690 V and 800 V?

Both voltage options use 100 A modules. The 30 A module is available at 200 and 400 V, while 480 V options start at 50 A.

What current THD should I expect after filtering?

The product specification lists THDi below 5% under typical conditions. Actual results depend on filter capacity, load spectrum, background distortion and the measurement point. Verify the outcome at the agreed point under comparable loads before and after filtering.

Does Sucyc-AHF support N+1 redundancy?

Yes. The series supports N and N+1 configurations. In an N+1 design, confirm that the remaining modules can meet the required compensation current when one module is unavailable.

Should I use open-loop or closed-loop CT sensing?

The series supports either configuration. Select the sensing arrangement according to the measurement boundary and parallel control design, then confirm CT and communication requirements against the approved documentation.

How many modules fit in one cabinet?

One cabinet supports up to five modules and up to 1,000 A, depending on the selected voltage and module ratings. Confirm the actual capacity against the configuration and cabinet cooling requirements.

How is an AHF sized?

Size an active harmonic filter (AHF) from measured harmonic currents. Verify system voltage, wiring and the harmonic orders that need compensation.